3.7.2 Home tab
Once connected, the app main screen is displayed: Home tab. This tab
displays the concentration measured in real time by the gas detector and
the device status on the “Status ring”. For details on the “Status ring”, see
the table below.
The following are also available:
pop-up menu, top left, to access app information and basic settings ;
red function buttons in the centre of the screen;
app tabs, on the tab bar, at the bottom of the app screen.
Status Status ring Description
Warm-up Green Gas detector stabilising after power on or
restart
Normal Green Normal operation
Low alarm Yellow The gas measurement has exceeded the
low alarm set point
High alarm Red The gas measurement has exceeded the
high alarm set point
Offline Orange Gas detector in maintenance mode, not
actively monitoring gas
Fault Orange A fault has been detected
Negative gas fault Orange Gas detector calibration deviates below
zero, zero calibration required
Zero cal. fault Orange An error occurred during zero calibration.
Zero calibration was not updated. Zero
calibration required.
Full-scale cal. fault Orange An error occurred during full-scale calibra-
tion. Full-scale calibration was not updated.
Full-scale calibration required.
Tab. 3.e
4
2
1
3
7
7
8
9
6
No. Description
1 Pop-up menu
2 Status ring
3 Calibrate button
4 Details button
5 Disconnect button
6 Restart button
7 Test tab
8 Configure tab
9 Logs tab
Fig. 3.e
Tab. 3.f
3.7.3 Pop-up menu
The pop-up menu is accessible in the top left corner in all tabs. The
following sub-menus can be selected:
Settings
View logs
End user license agreement
About
The “Settings” sub-menu is used to enter information for preparing the
calibration reports, automatically generated by the app in PDF format
at the end of each calibration procedure. The information that can be
entered includes customer and operator details, logo and email address
to send the report to.
The View logs” sub-menu shows a list of previous calibrations and bump
tests and corresponding reports. The list can be cleared by pressing the
“Clear button. The calibration reports can also be viewed in the “Logs”
tab, accessible from the tab bar at the bottom of the app screen.
The “End user license agreement” sub-menu shows the agreement or
EULA that defines the specific use of the Rileva app.
The About sub-menu shows the current version of the RILEVA app
installed on the device and reference to the www.carel.com website.
3.7.4 Function buttons
The function buttons provide quick access to the most important
functions of the GLD gas detector. In particular, the Home tab has four
buttons:
Calibrate button
Disconnect button
Restart button
Details button
The Calibrate button opens the calibration and bump test section of the
app. For details on this section, see paragraph “4.2 - Calibration and bump
test”.
The Disconnect button is used to disconnect the Bluetooth connection
between the device and the smartphone. Press it when all of the
installation or maintenance operations have been completed.
The Restart button is used to restart the device without disconnecting
power. The device will repeat the start-up sequence and the warm-up
phase.
The Details button accesses the section on device information, as shown
in the example screen below.
Fig. 3.f
In particular, the Details section includes:
Last fault: hexadecimal fault code, see the table in paragraph “4.3 -
Troubleshooting”. Furthermore, the entry can be expanded to read the
entire error message. A list is shown of the most recent errors detected
by the device.
Alias: name assigned to the device.
UID: gas detector identification code.
Firmware version: current FW version installed.
Low alarm set point: low alarm activation level, in ppm.