EasyManua.ls Logo

Carel GDSBI20C00 User Manual

Carel GDSBI20C00
84 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
MANUALE D’USO
Gas Leakage Detector
+0300047IE - ITA/ENG
Up to date version available on
www.carel.com
USER MANUAL
Gas Leakage Detector
Per applicazioni commerciali e industriali
For commercial and industrial applications
Question and Answer IconNeed help?

Do you have a question about the Carel GDSBI20C00 and is the answer not in the manual?

Carel GDSBI20C00 Specifications

General IconGeneral
ProtectionIP65
Product TypeGas Detector
ModelGDSBI20C00
Power Supply24 Vac/dc
Output Signal4-20 mA
Detection GasRefrigerant
Detection PrincipleInfrared
Operating Humidity Range0% to 95% RH (non-condensing)
CertificationCE

Summary

GENERAL WARNINGS

General Safety and Handling Warnings

General warnings for product use, environment, and handling, including ESD precautions.

1. PRODUCT DESCRIPTIONS

2. INSTALLATION

Installation Procedures and Notes

Step-by-step mounting, wiring, and additional notes for device installation.

3. OPERATION

Device Configuration: Rotary Switch & App

Instructions for configuring the device using the rotary switch and the RILEVA TE app.

Rotary Switch Parameter Settings

Explanation of how to set parameters using the rotary switch and voltage conversion table.

Alarm Management and Setpoints

Explains alarm activation and provides default alarm setpoints for different gas groups.

Alarm Thresholds and Gas Detection

Lists alarm setpoints for gas groups and details detected gases.

RILEVA TE App Features

Overview of RILEVA TE app features for configuration and maintenance.

Modbus Network Configuration

MAINTENANCE

Calibration Procedure

Procedure for periodic sensor calibration using a calibration kit and its necessity.

Calibration via App

Step-by-step guide for performing calibration using the RILEVA TE app.

App-Guided Fresh Air Calibration

Steps for performing fresh air calibration using the RILEVA TE application.

App-Guided Span Gas Calibration

Procedure for span gas calibration using the RILEVA TE app, including reference values.

Span Calibration & Environmental Data

Completing span calibration and entering temperature/humidity for calibration certificate.

Calibration Summary & Report Generation

Reviewing calibration summary, saving data, and generating a PDF calibration report.

Calibration via Modbus Communication

Instructions to perform zero and span calibration via Modbus communication.

Modbus Calibration Register Operation

Flowchart illustrating the sequence and logic for Modbus calibration registers.

Sensor Replacement Procedure

Detailed procedures for replacing the sensor in the device.

Built-in Version Sensor Replacement

Detailed instructions for replacing the sensor in the built-in version of the device.

Remote Version Sensor Replacement

Detailed instructions for replacing the sensor in the remote version of the device.

Technical Specifications

Related product manuals