Unit installation
Read this instruction manual thoroughly before starting
installation.
This unit complies with the low-voltage (2006/95/EC) and •
electromagnetic compatibility (2004/108/EC) directives.
The unit should be installed according to the national standards on •
plants.
Follow all current national safety code requirements. In particular •
ensure that a properly sized and connected ground wire is in place.
Check that the voltage and frequency of the mains power supply are •
as required for the unit to be installed; the available power source
must be adeguate to operate all other appliances connected to the
same line. Also ensure that national safety code requirements have
been followed for the main supply circuit.
Where necessary, use eld-supplied 25 mm I.D. PVC pipe of •
appropriate length and with the correct thermal insulation for the
condensate drain extension.
After installation thoroughly test system operation and explain •
all system functions to the owner. Use this unit only for factory
approved applications: the unit cannot be used in laundry or
steam pressing premises.
WARNING: Disconnect the mains power supply switch before
servicing the system or handling any internal parts of the unit.
The manufacturer declines any liability for damage resulting from •
modications or errors in the electrical or water connections. Failure
to observe the installation instructions, or use of the unit under
conditions other than those indicated in Table "Operating limits"
of the unit installation manual, will immediately invalidate the unit
warranty.
Failure to observe electric safety codes may cause a re hazard in the •
event of short circuits.
Inspect equipment for damage during transport. In case of damage •
le an immediate claim with the shipping company. Do not install or
use damaged units.
In case of malfunction turn the unit o, disconnect the mains power •
supply and contact a qualied service engineer.
Maintenance must only be carried out by qualied personnel.•
All of the manufacturing and packaging materials used for this •
appliance are biodegradable and recyclable.
Dispose of the packaging material in accordance with local •
requiremements.
Choosing the installation site
Positions to avoid:
Exposure to direct sunlight.•
Areas close to heat sources.•
On damp walls or in positions that may be exposed to water hazard.•
Where curtains or furniture may obstruct free air circulation.•
Recommendations:
Choose an area free from obstructions which may cause uneven air •
distribution and/or return.
Consider using an area where installation is easy.•
Choose a position that allows for the clearances required.•
Look for a position in the room which ensures the best possible air •
distribution.
Install unit in a position where condensate can easily be piped to an •
appropriate drain.
General Information
“Hydronic Global Cassette Fan Coil Units
Models
C= 2-pipe
D= 4-pipe
Models with electric heater
Models
C= 2-pipe
42GWC004B 42GWE004B 42GWC004B-3
42GWC008B 42GWE008B 42GWC008B-3
42GWC010B 42GWE010B 42GWC010B-3
42GWC012B 42GWE012B 42GWC012B-3
42GWC016B 42GWE016B 42GWC016B-3
42GWC020B 42GWE020B 42GWC020B-3
42GWD004B 42GWH004B
42GWD008B 42GWH008B
42GWD010B
42GWD020B
230V ~ 50Hz 230V ~ 50Hz 230V ~ 60Hz