4
OUTDOOR
COIL TYPE
UNIT J K H
48LC 07 RTPF
49 3/8
[1253]
36 3/8
[925]
27 7/8
[708]
NOTES:
1. DIMENSIONS ARE IN INCHES, DIMENSIONS
IN [ ] ARE IN MILLIMETERS.
2. CENTER OF GRAVITY
3. DIRECTION OF AIR FLOW
BACK
INDOOR COIL
ACCESS PANEL
FILTER ACCESS PANEL
(TOOL-LESS)
CONDENSER
COIL
4-5/8
[118]
35-7/8
[912]
6-5/8
[168]
59-1/2
[1510]
H
3-3/4
[95]
9-7/8
[251.50]
9-3/8
[238.52]
CONDENSER
COIL
LEFT
A,
B,
G
D
ELECTRICAL
DISCONNECT
LOCATION
C
OPTIONAL
FACTORY
INSTALLED
CONVENIENCE
OUTLET
6-1/4
[160]
J
8-3/8
[214]
37
[940]
88-1/8
[2238]
2-5/8
[66]
TYP
CURB
WIDTH
INDOOR BLOWER
ACCESS
CONTROL BOX
ACCESS PANEL
FRONT
F
OPTIONAL FACTORY
INSTALLED
DISCONNECT OR HACR
HANDLE
HANDLE
TYP
CURB
WIDTH
4-3/8
[112]
K
12-5/8
[321]
5-3/4
[146]
41-7/8
[1065]
37-7/8
[962]
13-7/8
[353]
28-3/8
[720]
SUPPLY AIR
5-3/4
[146]
7
[177]
1-1/4
[32]
26
[659]
RETURN
AIR
RETURN
AIR
SUPPLY
AIR
RIGHT
OUTSIDE
AIR
BAROMETRIC
RELIEF
FLOW
E STD.
CONDENSATE
DRAIN
FILTER
RETURN
AIR
20-3/4
[526]
40-3/8
[1026]
12-5/8
[321]
36-3/8
[925]
RETURN AIR
25-1/2
[647]
40-3/8
[1027]
37-5/8
[955]
28-3/4
[731]
SUPPLY
AIR
6-1/4
[159]
14
[356]
3-1/4
[83]
14
[355]
11
[279]
29-5/8
[751]
18
[469]
16
[412]
4
[100]
W
X
Y
Z
ECONOMIZER HOOD
(OPTIONAL)
RETURN
AIR
SUPPLY
AIR
TOP
E ALT.
CONDENSATE
DRAIN OPENING
IN BASEPAN
SEE THRU
THE BASE
CHART
FLUE
HOOD
A
48LC500391
48LC 07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
-05/08/13
REVSUPERCEDESDATE
SUBMISSION OF THESE DRAWINGS OR DOCUMENTS
DOES NOT CONSTITUTE PART PERFORMANCE OR
ACCEPTANCE OF CONTRACT.
THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION
AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE
CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT CARRIER
CORPORATION'S WRITTEN CONSENT.
UNITED
TECHNOLOGIES
CARRIER
P.O. BOX 4808
SYRACUSE, NY
13221
THRU-THE-BASE CHART (FIELD INST)
THESE HOLES REQUIRED FOR USE WITH ACCY KITS:
CRBTMPWR002A01: GAS THRU CURB
CRBTMPWR004A01: GAS THRU BASEPAN
THREADED
CONDUIT SIZE
WIRE
USE
REQ'D HOLE
SIZES (MAX.)
W 1/2" ACC. 7/8" [22.2]
X 1/2" 24V 7/8" [22.2]
Y 1 1/4" (002,004) POWER 1 3/4" [44.4]
Z * (004) 3/4" FPT GAS 1 3/4" [44.4]
*
(002) PROVIDES 3/4" FPT THRU CURB
FLANGE & FITTING. HOLE SIZE: 2" [50.8]
THRU-THE-BASE CHART (FIOP)
FOR "THRU-THE-BASEPAN" FACTORY OPTION,
FITTINGS FOR ONLY X, Y, & Z ARE PROVIDED. **
**
FOR BELOW LISTED MODELS, A FIELD
SUPPLIED 1/2" ADAPTER IS REQUIRED
BETWEEN BASE PAN FITTING AND GAS VALVE:
SHEET
1 OF 2
CONNECTION SIZES
A 1 3/8" [35] DIA FIELD POWER SUPPLY HOLE
B 2 1/2" [64] DIA POWER SUPPLY KNOCKOUT
C 1 3/4" [51] DIA GAUGE ACCESS PLUG
D 7/8" [22] DIA FIELD CONTROL WIRING HOLE
E 3/4"-14 NPT CONDENSATE DRAIN
F 3/4"-14 NPT GAS CONNECTION
G 2 " [51] DIA POWER SUPPLY KNOCK-OUT
C13312
Fig. 2 -- Unit Dimensional Drawing
48HC48LC