62-11491 8
STARTING UNIT - STANDBY OPERATION (CONTINUED)
1. Place the unit RUN/STOP switch in the “STOP” position.
2. Place the I/O switch in the “O” position.
3. Connect the standby cable to the unit and then turn the external
power circuit breaker on. (See table in Standby Guidelines
section.)
4. Place the desired compartment switch(es) in the “ON (I)” position.
5. Place the unit RUN/STOP switch in the “RUN” position.
6. Place the I/O switch in the “I” position.
7. Press the STANDBY key.
Under normal circumstances this is all that is required to run the unit in
standby power. The unit will then perform a complete diagnostic check on
the microprocessor controller and start automatically.
Complete the Pre-Trip Inspection as described in a previous section.
BOX TEMPERATURE
AUTO START/STOP
I
UNIT DATA
PRETRIP
ALARM/FAULT
STANDBYBUZZER OFF
MAN
DEFROST
CITY
SPEED
ROAD
FUNCTION
ENTER
SETPOINT
O
i
--20 35° F
COMPARTMENT 1 COMPARTMENT 2 COMPARTMENT 3