21 62-12002
OVR SWITCH Indicates if the remote switch
1 alarm should override the
shutdown of the unit. If the
Override Remote Switch 1
Shutdown functional
parameter = Yes, the remote
switch 1 alarm controller
response is alarm only
regardless of the configuration
parameter. Low speed Alarm
only could still be applicable.
0 - No
1 - Yes
Default: No
Airflow function. Normal Air =
no effect
High Air = SPEED = HIGH in
Perishable Range.
0 - Normal Air
1 - High Air
Default: Normal Air
Start/stop shut down offset for
frozen
0°F to 1.1°F
0°C to 0.6°C
Default: 0
Display alarm description in
alarm list
0 - No
1 - Yes
Default: Yes
Top Freeze Protection: If Yes,
use supply air temperature as
active probe
If No, use selected probe in
Temp Control setting
This can only be turned on
when
0 <= setpoint <= 18.4 °C.
It will be automatically turned
to NO if system is set outside
of these conditions or if the
SAT probe is bad.
0 - No
1 - Yes
Default: No
Functional Parameters (Continued)