3
FEATURES AND BENEFITS
S Single cooling stage models are available from 3 -- 10 ton.
S Two cooling stage models are available from 7.5 -- 15 ton.
S SEER up to 13.0.
S EER’s up to 11.1.
S IEER’s up to 11.8 with single speed indoor fa n motor and up to 12.8 with 2--speed/VFD indoor fan motor.
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time and
money on replacement jobs.
S Standardize d compone nts and layout. Standardized compone nts and controls make service a nd stocking parts easier.
S Scroll compressors on all units. Thi s makes service, stocking parts, replacement, and t roubleshooting easier.
S Field convertible airflow (3 -- 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to
overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical
to horizontal.
S Easy-- adjust, belt--drive motor available.
S Provisions for bottom or side condensat e drai n.
S Capable of thru--the--base or thru--the--curb gas line routing.
S Single--point gas / electrical connection.
S Sloped, composite dra in pan sheds water; and won’t rust.
S Standardize d control s & control box layout. Standardized components & controls make stocking parts & service easier.
S Tool --less filter access door.
S Clean, large, easy to use cont rol box.
S Color--coded wiring.
S Large, lam inate d wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
S Single, central term inal board for test and wiring connections.
S Fast--access, handled, panels for easy access on normally accessed service panels.
S “No--strip” screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or
the unit.
S Mechanical cooling (115_Fto40_For46_Cto4_C) standard on all models. Winter Start Kit allows cooling operation
downto25_F(--4_ C) and MotorMaster to --20_F(--29_C).
S High efficiency, gas heat with induced--draft flue exhaust design.
S Induced draft motor ensures no flue gas can escape into the indoor air stream.
S Carrier designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be
periodicall y, manually drained. This saves la bor and maintenance expense.
S 2 --in (51mm) disposable filters on all units.
S Refrigerant filter --drier on each circuit.
S Each circuit is protected with a high and low pressure switch.
S Many factory--installed options ranging from air management economizers, 2 position dampers, plus convenience
outlets, disconnect switches and smoke detectors.
S Standard (parts only) Warranty: 10 yr. alum inize d heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr.
parts.
S Factory--installed Humidi--MiZerr
adapt ive dehumidification system on all sizes with round tube / plate fin condenser
coils, includes MotorMaster I controller.
S Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor
fan motor speed between cooling stages. Available on 2--stage cooling models 08--16 with electromechani cal controls or
RTU Open.