Carrier service manual R410a DC Inverter 60Hz
Specification & Performance 19
1. Specifications
Independent unit specifications
Model
38VF008H117010 38VF010H117010 38VF012H117010
Power supply V-Ph-Hz 208-230V 3~60Hz 208-230V 3~60Hz 208-230V 3~60Hz
Cooling (*1)
kW 25.2 28 33.5
Btu/h 86000 95500 114300
Input kW 5.875 7.053 8.793
EER kW/kW 4.29 3.97 3.81
Heating (*2)
Capacity
kW 27 31.5 37.5
Btu/h 92100 107500 128000
Input kW 6.15 7.554 8.993
COP kW/kW 4.39 4.17 4.17
DC inverter compressor
Model E655DHD-65A2YG E655DHD-65A2YG
E655DHD-65A2YG
+E405DHD-36A2YG
Quantities 1 1 1+1
Brand Hitachi Hitachi Hitachi
Capacity Btu/h(W) 107800(31590) 107800(31590)
107800(31590)+
40300(11800)
Input W 10340 10340 10340+3665
Operating frequency Hz 40~200 40~200 40~200/ 60~180
Power supply V-Ph-Hz 208-230V, 3~60Hz 208-230V, 3~60Hz 208-230V, 3~60Hz
Crankcase W 27.6×2 27.6×2 27.6×2×2
Refrigerant oil gal.(ml) FVC68D/ 0.132(500) FVC68D/ 0.132(500)
FVC68D/
0.132+0.132(500+500)
Outdoor fan motor
Model WZDK560-38G(B) WZDK560-38G(B) WZDK750-38G-4
Type DC motor DC motor DC motor
Brand Panasonic&Nidec Panasonic&Nidec Panasonic&Nidec
Quantities 1 1 2
Insulation class E E E
Safe class IPX4 IPX4 IPX4
Input W 540(rated) 540(rated) 270×2(rated)
Output W 450(rated) 450(rated) 230×2(rated)
Speed r/min 850(rated) 850(rated) 930(rated)
Outdoor fan
Material Plastic Plastic Plastic
Type Axial Axial Axial
Fan Quantities 1 1 2
Dimension(Diameter × H) in.(mm) 27-9/16×8(700×202) 27-9/16×8(700×202)
22×7-7/16(560×189)+
22-1/8×6-3/8(562×162)
Vane Quantities of each
blower
3 3 3+4
Outdoor coil
Number of rows 2 2 2
Tube pitch(a) × row
pitch(b)
in.(mm) 7/8×3/4(22×19) 7/8×3/4(22×19) 7/8×3/4(22×19)
Fin spacing in.(mm) 1/16(1.6) 1/16(1.6) 1/16(1.6)
Fin type Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum
Tube outside diameter  in.(mm)  5/16(Ф7.94)  5/16(Ф7.94)  5/16(Ф7.94) 
Tube type Inner-grooved Inner-grooved Inner-grooved
Coil length × height in.(mm)
78-5/32×48-1/2
(1985×1232)
78-5/32×48-1/2
(1985×1232)
89-3/8×48-1/2
(2270×1232)
Number of circuits 22 22 22
Outdoor air flow CFM(m
3
/h) 6620(11242) 6620(11242) 7660(13000)
External static pressure in.WG(Pa)
0~0.08(0~20) (default);
0.08~0.16(20~40)
(optional)
0~0.08(0~20) (default);
0.08~0.16(20~40) (optional)
0~0.08(0~20) (default);
0.08~0.24(20~60) (optional)
Outdoor sound level (*3) dB(A) 57 57 59
Outdoor unit
Dimension(W×H×D) in.(mm)
37-25/32×63-9/16×30-1/8
(960×1615×765)
37-25/32×63-9/16×30-1/8
(960×1615×765)
49-7/32×63-9/16×30-1/8
(1250×1615×765)
Packing(W×H×D) in.(mm)
40-3/8×70-1/2×32-11/16
(1025×1790×830)
40-3/8×70-1/2×32-11/16
(1025×1790×830)
51-3/8×70-15/32×32-9/32
(1305×1790×820)