Carrier service manual R410a DC Inverter 60Hz
Specification & Performance 31
6. Operation Limits
50
45
40
35
30
25
20
15
10
5
0
-5
-10
10
15
25 30 35
20
Range for continuous operation
Range for intermittent operation
O u t d o o r t e m p e r a t u r e ( D B )
I n d o o r t e m p e r a t u r e ( W B )
Cooling
30
25
20
15
10
5
0
-5
-10
10
15
25 30 35
20
Range for continuous operation
Range for intermittent
operation
O u t d o o r t e m p e r a t u r e ( W B )
I n d o o r t e m p e r a t u r e ( D B )
Heating
-15
-20
Notes:
1. If the system is running in cooling mode, when the ambient temperature is lower than -5 or higher than 48, the
units will stop running for protection control.
2. These figures base on the operation conditions between indoor units and outdoor units:
Equivalent pipe length is 5m, and height difference is 0m.
Precaution:
The indoor relative humidity should be lower than 80%. If the air conditioner works in an environment with a relative
humidity higher than mentioned above, the surface of the air conditioner may condensate. In this case, it is recommended
to set the air speed of the indoor unit to high.