62-11637 6–4
TECHNICIAN RESET REQUIRED
(AL00021)
AL00011 (Low Engine Oil Pressure) or AL00012 (High Coolant Tempera-
ture) has been activated three times in the last two hours and the unit has
been locked out. Refer to Section 7 for further information.
TIME SELECTION NOT CHANGED
A time change was started but not entered (saved) in Configuration
List.
TRIP START ENTERED The Trip Start marker has been placed in the DataLink data recorder.
UNIT BATTERY TOO LOW The unit battery has dropped below 7 volts for more than 10 seconds.
UNIT SHUTDOWN − DOOR OPEN The unit has shutdown because the refrigerated compartment door is
open.
UNIT SHUTDOWN − SEE ALARM
LIST
An active shutdown alarm has shut the unit down.
UNIT SHUTDOWN − RMS1 The unit has shutdown because switch is open. May be connected to a
door or a remote control switch.
USE UP/DOWN KEY TO SCROLL USE
= KEY TO SELECT ITEM TO CHANGE
Items available are being displayed or additional items are available for
selection. Use the up or down arrow key to highlight or display and high-
light the desired selection and then use the “=” key to select it.
VIEWING MENU SOFTKEY SELEC-
TIONS PRESS MENU KEY TO
SCROLL
Additional soft key selections are available and the MENU key is to be
used to scroll and view them.
WARNING: NO TEMP CONTROL
The temperature sensors have failed and the unit has entered
Cargo Pro-
tect Mode. Refer to Section 4.11.1.
Table 6–1 MessageCenter Messages
Message Description