EasyManua.ls Logo

Carrier X4 7300 - 00031 Failed to Start - Auto Mode

Carrier X4 7300
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62-11637 7–16
00031 FAILED TO START - AUTO MODE
ACTIVATION: Engine has tried to start three times unsuccessfully.
UNIT CONTROL: Shutdown and alarm.
RESET CONDITION: Alarm may be manually reset using the display mounted keys or by turning the unit
off, then back on again. If the Configuration is set to Rail Mode, this alarm will reset after 4 hours. Rail
alarm reset will be recorded in the data recorder.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in Notes Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1. Check For Additional Alarms
a. If this alarm is activated in conjunction with other alarms (00041, 00072, 00078, 00079, 00080,
00085 or 00086) check F5 & F10. Fuses must be good. Replace fuse(s) as required. Clear alarms,
restart and check for repeat alarm(s).
2. Check For Low Fuel Level
Check fuel level in the fuel tank. Add fuel as needed to the fuel tank.
3. Check for Alarms
Check for Alarm 40 (Check Glow Plug) and Alarm 35 (Check Starter Circuit). Alarm conditions must be
corrected and the alarm cleared to continue.
4. Check Engine Control Unit (ENCU) and Fuel Speed Actuator (FSA)
a. Check voltage from fuse F3 through PCM34 and SP6 to ENCU22. Verify correct fuse, see Fig-
ure 2.7. Must have minimum 11 VDC with the battery connected and SROS in the OFF position.
b. Check voltage from 3MM-9 to ENCU44. Must have minimum 11 VDC with SROS in the START/
RUN position. If not, energize the run relay output using component test mode (refer to Section
5.2.4) and retest.
c. Check for ground at ENCU-19 and ENCUGNDA (at the battery negative cable connection). If ground
not good, check connectors and wiring between terminals for damage, moisture or corrosion.
d. Inspect fuel/speed actuator (FSA), engine speed sensor (ENSSN) and engine speed control unit
(ENCU) connector pins & terminals. Verify no physical damage to components, and no damage or
corrosion in connectors.
e. Check resistance & amp draw of FSA. Refer to Section 2.10 for specifications.
f. Check FSA plunger. Must move in and out freely. Refer to engine manual.
5. Check Engine Air-intake System
a. Check air cleaner indicator. Flag must not be visible.
b. Inspect air intake system. Verify hoses & tubes in good condition, with no kinks or restrictions.
6. Check For Correct Engine Oil
Check viscosity is correct for ambient conditions. Refer to Section 2.7.
7. Check Engine Exhaust System
Inspect the exhaust system. Must be clear and unobstructed.
8. Check Engine
Check engine compression. Refer to Engine Workshop manual.

Table of Contents