3–17 62-11637
Table 3–1 Unit Data
DATA DEFINITION
ENGINE
FUEL LEVEL
This is only displayed when the optional sensor is installed and config-
ured YES. Displays % of fuel in tank.
BATTERY Battery voltage
AMP DRAW Battery charging or discharging amps
ENGINE COOLANT TEMP Engine coolant temperature
ENGINE SPEED Engine revolutions per minute
ENGINE LOAD Engine Rack (Throttle) Position (% open)
REFRIGERATION SENSORS
AMBIENT AIR TEMP Ambient (air entering condenser) air temperature
RETURN AIR TEMP Return (air entering evaporator) temperature
SUPPLY AIR TEMP Supply (air leaving evaporator) temperature
DELTA-T
Supply air temperature minus return air temperature (A negative value
indicates cooling and a positive value indicates heating.)
DEFROST TERM TEMP Defrost termination temperature
REMOTE SENSORS
REMOTE SENSOR (1-2)
This is the temperature at remote Temperature Sensor 1 or 2. (These
sensors are optional, and may not be applicable to this unit.)
REFRIGERATION SYSTEM
DISCHARGE PRESSURE Refrigerant pressure leaving the compressor
COMPRESSOR DISCHARGE TEMP Refrigerant temperature leaving the compressor
SUCTION PRESSURE Refrigerant pressure entering the compressor
SUCTION LINE TEMP Refrigerant temperature entering the compressor
EVAPORATOR PRESSURE Refrigerant pressure leaving the evaporator
EVAPORATOR OUTLET TEMP Refrigerant temperature leaving the evaporator
SUCTION MOD VALVE % open of CSMV
EXPANSION VALVE % open of EVXV
SYSTEM INFORMATION
DATE
This is the current Date and Time that the system is using. This may be
different than your actual time, depending on the time zone and day-
light-saving time selections made by the owner of the unit.
TIME
NOTE: The system uses a 24 hour clock. Hours 00 to 11 are AM and
hours 12 to 23 are PM.
TRAILER ID # Trailer ID (as entered by the user)
UNIT SERIAL # Unit serial number
UNIT MODEL # Unit model number (number entered in Configuration)
MICRO SOFTWARE REVISION Revision of software that is operating the main microprocessor module
DISPLAY SOFTWARE REVISION Revision of software that is operating the display module
REMOTE SOFTWARE REVISION Revision of software that is operating the Remote display (If installed)
MAIN MICROPROCESSOR SERIAL
NUMBER
Serial Number of the main microprocessor module
INSTALLED OPTIONS (Will display if one or more options are installed)
INTELLISET If displayed, the IntelliSet option is installed.
DATATRAK If displayed, the DataTrak option is installed.