62-11637 3–24
In ambients above 32°F (0°C), the unit will run as above, and will monitor battery voltage and charging amps only
(according to the Configuration setting).
In ambients below 32°F (0°C), the unit will run for 20 minutes minimum run time, then restart every 60 minutes
(maximum off time). Battery voltage and amperage will be monitored normally.
1. To place the unit in Sleep Mode, enter the Advanced User Functional parameter screen as described in
Section 3.16.
2. 2. Press the DOWN ARROW key until the START-STOP SETTINGS sub-menu is highlighted and then
press the “=” key to enter the menu.
3. Press the DOWN ARROW key until the Functional Parameter “SLEEP MODE SETTINGS” is highlighted.
Press the “=” key.
4. Press either the UP or DOWN ARROW key until “ON” is highlighted. Press the “=” key to save the setting to
memory, the unit is now in Sleep Mode.
5. Additional Functional Parameter sub menu selections for “wake up time” and “run pretrip at wake” will now
be available and may be saved to memory following the key stroke sequence in the preceding step. Refer to
the following for information on these settings.
TO EXIT SLEEP MODE
Place the START/RUN-OFF switch in the OFF position, then back to the START/RUN position.
CONTINUOUS
START/STOP
MENU
ALARM
COOLDIESELSTART/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
COOLDIESELSTART/STOP
LANGUAGE
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
DATA
RECORDER
FUNCTIONS EXIT
1
2
BACK EXIT
ECONOMY SETTINGS
TEMPERATURE SETTINGS
START-STOP SETTINGS
VIEWING PREFERENCES
FUNCTIONAL PARAMETERS (3 OF 4)
END OF LIST