4 - INSTRUMENTS/CONTROLS
40
4. SENSOR INDICATOR PANELS - The sensor
indicator panels have marks 1 through 4. The
panels illuminate ON and OFF as material hits
the sensors (this indicates the sensors are
working). Panels 1 and 2 are for the chaffer
sensors. Panels 3 and 4 are for the rotor cage
sensors.
NOTE: The illumination of the panels must only be
used as an indication that the sensors are working
and not for the actual amount of loss.
5. METER - The meter pointer indicates an
increase or decrease in grain loss from the
acceptable level for which the monitor has been
adjusted. The change in the meter indication is
used by the operator as a guide on how to
change the harvesting operation, i.e. to speed
up, slow down or make adjustments.
NOTE: The meter registers only kernels seen in a
time mode at less than 0.5 mph (0.8047 km/h).
495L94
4
5