Loading...
― 41 ―
4.8 ERROR CODE LIST
Program
No.
Program
Name
Nature of error Error Sub 1 Sub 2 Sub 3 Sub 4
1 RAM Data verify error 0100 Address Read data Write data Write data
2 FROM Erase error
Red LED lights
Program stops
Write error
Data verify error
3 LCD
4 IrDA CLR Exit 0400
Data verify error 0401
5 Ls_Scan 0500
0501
0502
0503
0504
0505
0506
6 Matrix
7 TRG/MF
8 ONKEY CLR Exit 0800
9 MBC CLR Exit 0900
10 INIT CLR Exit 1000
Status error 1001
11 Ls_LP Status error 1100
Expectation value
Status
Status error 1101
Expectation value
Status
Status error 1102
Expectation value
Status
Status error 1103
Expectation value
Status
12 Ir_CUN
13 IrDA_LP CLR Exit 1300
Data verify error 1301 Send data Receive data
CLR Exit 1302
Data verify error 1303 Send data Receive data
14 14p_LP Status error 1400
Expectation value Expectation value
Data short 1401
Data verify error 1402 Send data Receive data
CLR Exit 1403
15 15p_LP Status error 1500
Expectation value
Read data
Data short 1501
Data verify error 1502 Send data Receive data
CLR Exit 1503
16 IRQ7_S CLR Exit 1600
17 LB0 CLR Exit 1700
Status error 1701
Battery type error 1702
18 LLB0 CLR Exit 1800
Status error 1801
Battery type error 1802
19 LB-1 CLR Exit 1900
Status error 1901
20
21 Sleep
22 Dummy
23 Vib
24 RAM2 Data verify error 2400 Address Read error Write error
25 BT Status error 2500