28
While the system is being within “main programming menu” select section [026] to establish how the system will react in case of keypad alarm. The 1 to 6 options will be displayed
according to the table below:
(first part – partition A)
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
*
enabled disabled “Keypad Medical Emergency”([1]+[3])
KpdMedEmerg A Enable k1 Disable k1
[2] 2
*
enabled disabled
“Keypad maintenance request”([4]+[6])
MaintenanceReq A Enable k2 Disable k2
[3] 3
*
enabled disabled “Keypad Fire”([7]+[9])
KpdFire A Enable k3 Disable k3
*
enabled disabled “Keypad Panic” ([*]+[#])
KpdAlarm A Enable k4 Disable k4
[5] 5
enabled
*
disabled “Keypad Medical Emergency” with siren
MedEmerg A Enable Siren k5 Silent k5
[6] 6
*
enabled disabled “Keypad Panic” with siren
Panic A Enable Siren k6 Silent k6
Note: The default programmed options are marked with *.
Press the [1] to [6] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting first set of options, press [#] key to confirm. The keypad buzzer will sound 3 beeps and will display next 1 to 6 options according to the table below:
(second part – partition B)
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
*
enabled disabled “Keypad Medical Emergency”([1]+[3])
KpdMedEmerg B Enable k1 Disable k1
[2] 2
*
enabled disabled
“Keypad maintenance request”([4]+[6])
MaintenanceReq B Enable k2 Disable k2
[3] 3
*
enabled disabled “Keypad Fire”([7]+[9])
KpdFire B Enable k3 Disable k3
[4] 4
*
enabled disabled “Keypad Panic” ([*]+[#])
KpdAlarm B Enable k4 Disable k4
[5] 5
enabled
*
disabled “Keypad Medical Emergency” with siren
MedEmerg B Enable Siren k5 Silent k5
[6] 6
*
enabled disabled “Keypad Panic” with siren
Panic B Enable Siren k6 Silent k6
Note: The default programmed options are marked with *.
Press the [1] to [6] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [026] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Section [027] – Quick arming features in partitions
While the system is being within “main programming menu” select section [027] to establish the Quick arming features. The 1 to 5 options will be displayed according to
the table below: (first part – partition A)
Key pressed
KP-126Pz / KP-164Pz (LED keypads) Description KP16LCD / KP16LCDL (LCD keypads)