46
FFFF
FFFF
[4] 4
*enabled disabled
PGM4 activating/deactivating
En/Dis PGM4 Allowed k4 Not allowed k4
[5] 5
*enabled disabled
PGM5 activating/deactivating
En/Dis PGM5 Allowed k5 Not allowed k5
[6] 6
*enabled disabled
PGM6 activating/deactivating
En/Dis PGM6 Allowed k6 Not allowed k6
4. Finally the installer should press [#] key to confirm the RIGHTS
2
set of the “master user code”.
After [#] key pressing the keypad buzzer will sound 3 confirmation beeps and the panel will pass to the next step.
By [#] key pressing, RIGHTS
3
set of the “master user code” can be maintained as it was previously established
5. The user code rights are displayable on 1 to 3 LEDs; in order to turn the rights activate/deactivate, the installer should press the 1 to 3 keys and the
appropriate LED will turn ON/OFF. If the a zone LED is ON that means the appropriate right is enabled and if the zone LED is OFF that means the right is disabled.
3
rd
set of rights
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
*enabled disabled
[2] 2
*enabled disabled
Stop guardian rounds
Stop Rounds Allowed k2 Not allowed k2
[3] 3
enabled disabled
Card controls access control PGM
types
Card control PGM Allowed k3 Not allowed k3
5.1 Finally installer should press [#] key to confirm the RIGHTS
2
set of the “master code”. After [#] key pressing the keypad buzzer will sound 6 confirmation beeps and
the control panel will go back within “main programming menu”.
Notes:
1. The “master code” has all the 16 rights enabled by default and they are programmable only by installer (only installer can change the 16 rights of the “master code” while he is
being within programming session of master code - section [046]).
2. Erasing of the “master code” IS NOT allowed. If, by mistake, installer is trying to erase the “master code” (by entering of [*] key instead of sequence of 4 or 6 digits while the control
panel just entered section [046]), the keypad buzzer will sound a long rejection beep and will exit the main programming menu. The control panel will keep the old value for “master code”.
Section [047]: First Panel Account for Identifying at CS
Enter 4 digits (HEX digits may be used), which will stand for first control panel account.
[x][x][x][x] (default value is [FFFF] )
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of the last one. Then the panel exits the section and will wait for a new command.
After any digit was pressed, programming of the first panel account may be canceled by [#] key pressing. After cancellation by [#] key pressing, the keypad buzzer will sound 6
confirmation beeps, the system will keep the old value for first panel account and the control panel will go back within “main programming menu”
To exit the “main programming menu”, press [#] key.
Notes:
1. By default, the first panel account is 0000.
2. Any time when the control panel is dialing the 1
-st
CS phone number, in order to identify itself to CS, the control panel will use the first panel account which is set in this section,
irrespective of way the alternate or split reporting option was set.
Section [048]: Second Panel Account for Identifying at CS2
Enter 4 digits (HEX digits may be used), which will stand for first control panel account.
[x][x][x][x] (default value is [FFFF] )
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of the last one. Then the panel exits the section and will wait for a new command.