Ev.codes S:063
010907030408
Ev.codes S:064
4142085655
Ev.codes S:065
0109070305
Ev.codes S:066
7570
Ev.codes S:067
2930111223
Section [063]: Event Reporting Codes in CID Format regarding: Arming by User / Keyswitch Arming / Arming by PC / “Timed Autoarming” /
Inactivity Autoarming / Away Quick Arming
Enter the last 2 digits of the Contact ID reporting code for each event.
Arming by user code 3.401 - Arming by user
Keyswitch arming 3.409 - Keyswitch arming
Arming by PC 3.407 - Remote arming
Timed autoarming 3.403 - Autoarming
Inactivity autoarming 3.404 - Late to arming
“Quick arming” 3.408 - “Quick arming”
Section [064]: Event Reporting Codes in CID Format regarding: “Stay Arming by User” / “Stay Keyswitch Arming” / “Quick Stay or Instant Stay
Arming” / “Partial arming” / “Fail to autoarm”
Enter the last 2 digits of the Contact ID reporting code for each event.
Stay Arming by User 3.441 - “Stay Arming”
“Stay keyswitch” arming 3.442 - “Stay keyswitch” arming
“Quick stay arming” 3.408 - “Quick Arming”
“Partial Arming” 3.456 - “Partial Arming”
Fail to auto arm 1.455 - “Fail to auto arm”
Section [065]: Event Reporting Codes in CID Format regarding: “Disarming by User / “Keyswitch Disarming / “Remote disarming by PC” / “Timed
autodisarming” / “Timed Autoarming Stopping”
Enter the last 2 digits of the Contact ID reporting code for each event.
Disarming by user code 1.401 - Disarming by user
Keyswitch disarming 1.409 - Keyswitch disarming
Disarming by PC 1.407 - Remote disarming
Timed autodisarming 1.403 - Automatic disarming
Stopped autoarming 3.405 - Deferred arming
Note: The code of "stopped autoarming" will be transmitted to CS by the panel, if during the 3 minutes before autoarming, while the keypad buzzer is warning that the system
will auto arm by time, autoarming is stopped by any valid user code
Section [066]: Event Reporting Codes in CID Format regarding: “Swinger-shutdown” zone bypassed / Zone Bypassed
Enter the last 2 digits of the Contact ID reporting code for each event.
Zone bypassed from swinger 1.575 - Swinger bypass
Zone/sensor bypassed 1.570 - Zone/sensor bypassed
Note: Upon arming the panel will transmit to CS the second reporting code of zone bypassing, if there are in the system:
- Bypassed zones by the panel in case of partial arming and the respective zones are as interior type and/or
Bypassed zones by the users using [*] [3] [User Code] or [BYPASS][User Code] commands.
Section [067]: Event Reporting Codes in CID Format regarding: “Guardian Rounds started” / “Guardian Rounds finished” / “Guardian Round
Failed” / “Ambush on Guardian Round
Enter the last 2 digits of the Contact ID reporting code for each event.
Guardian rounds started 1.429 - Access program mode entry
Guardian rounds finished 1.430 - Access program mode exit
Guardian round OK 1.611 - Point tested OK
Guardian round failed 1.612 - Point not tested
Ambush on guardian round 1.423 - Forced Access