54
Ev.codes S:068
30442010AA21
Ev.codes S:069
2130444545
Ev.codes S:070
010221AA26
Ev.codes S:071
010221AA26
- The specific event codes regarding „guardian rounds started” and „guardian rounds finished”, which are set in this section; after the 4-digit group specific to these reporting events the
panel will transmit to CS another 3-digit group which stands for user number identifying. In CID format the „guardian rounds started/finished by installer’s maintenance code” is
identifying as user „000” and the „guardian rounds started/finished by time” is identifying as user „999”.
- The specific event codes regardingguardian round OK”, „guardian round failed” and „ambush on guardian round”, which are set in this section; after the 4-digit group specific to these
reporting events the panel will transmit to CS another 3-digit group which stands for zone number identifying.
Section [068]: Event Reporting Codes in CID Format regarding: “Burglary Alarm” / “Tamper Alarm” / “Panic Alarm” / “Fire Alarm” / “Medical
Emergency Alarm” / “User under Duress (ambush)”
Enter the last 2 digits of the Contact ID reporting code for each event.
Burglary alarm 1.130 - Burglary alarm
Tamper alarm 1.144 - Sensor tamper
Panic alarm 1.120 - Panic alarm
Fire alarm 1.110 - Fire alarm
Medical emergency alarm 1.100 - Medical alarm
User under duress (ambush) 1.121 - Duress
Section [069]: Event Reporting Codes in CID Format regarding: “Keypad Lockout” / “Zone Alarm Restore” / “Tamper Alarm Restore” / Keypad
Tamper Alarm / Keypad Tamper Alarm Restore
Enter the last 2 digits of the Contact ID reporting code for each event.
Keypad lockout 1.421 - Access denied
Zone alarms restore 3.130 - Burglary alarm restore
Tamper alarm restore 3.144 - Sensor tamper
Keypad tamper alarm 1.145 - Expansion module tamper
Keypad tamper alarms restore 3.145 - Expansion module tamper restore
Section [070]: Event Reporting Codes in CID Format regarding: “AC power loss” / “Low Voltage on Battery” / “Bell Trouble” / “AUX overload” /
“System time and date not programmed” (Power ON)
Enter the last 2 digits of the Contact ID reporting code for each event.
AC power loss 1.301 - AC power loss
Low Voltage on Battery 1.302 - Battery test failure
BELL trouble 1.321 - Bell 1
AUX trouble 1.300 - System troubles
Time and date inaccurate 1.626 - Time and date inaccurate
Section [071]: Event Reporting Codes in CID Format regarding: “AC power Restore” / “Restore Voltage on Battery” / “Bell Trouble Restore” /
“System time and date Reprogrammed”
Enter the last 2 digits of the Contact ID reporting code for each event.
Restore AC power loss 3.301 - AC power Restore
Restore Voltage on Battery 3.302 - Battery test failure restore
Restore BELL trouble 3.321 - Bell 1 restore
Restore AUX trouble 3.300 - System troubles restore
Time and date reprogrammed 3.626 - Time and date inaccurate restore