55
Ev.codes S:072
272811122324
Ev.codes S:073
020616222254
Phone CS1
Unprogrammed
Enter the last 2 digits of the Contact ID reporting code for each event.
Programming entry 1.627 - Program mode entry
Programming exit 1.628 - Program mode exit
PC connected 1.411 - Call-back request made
PC disconnected 1.412 - Successful access
LOG 90% full 1.623 - Event LOG 90% full
LOG 100% full 1.624 - Event LOG overflow
Section [073]: Event Reporting Codes in CID Format regarding: Periodical Test / Panel Programming Changed / Maintenance Request / PGM
Activation by User / PGM Deactivation by User / Communication to CS failed
Enter the last 2 digits of the Contact ID reporting code for each event.
Periodical Test 1.602 - Periodic test report
Panel programming changed 1.306 - Panel programming changed
Maintenance request 1.616 - Service Request
PGM activation by users 1.422 - Access report by user
PGM deactivation by users 3.422 - Unused
Communication to CS failed 1.354 - Fail to communicate event
Notes:
1. In case of CID format was set by programming, then the control panel will transmit to CS the specific reporting codes regarding PGM activation/deactivation by users” which are set in this
section; after the 4-digit group specific to these reporting events the panel will transmit to CS another 3-digit group which stands for user number identifying. In CID format the installer’s
maintenance code” is identifying as user 000” and PC is identifying as user 255”.
2. In case in section [032] the alternate reporting was selected and if even after the 8 attempts for both CS phone numbers no central station answers, then the control panel will record a
“CS1 and CS2 communication failed” event into the 800-event LOG and a specific reporting code into the CS 85-event internal buffer, too. Upon a new reportable event occurring, if the
communication with CS is established, the entire list from CS internal buffer, the old reporting codes, the new reporting codes and the failed communication reporting code, which is already
in the list, will be reported together to the CS. For CS1 and CS2 communication failed” event, the panel will report to CS the 4-digit group which is established in this section, specific to
the “Communication to CS failed” event, after which the panel will add another 3 digits of [0], to identify at CS the CS1 and CS2 communication failed” event as zone “000”.
3. In case in section [032] the split (or double) reporting was selected, the panel will report the events as follows:
- Any event selected in section [033] to be reported to CS1 will be sent to the 1
-st
CS phone number, programmed in section [074]. If the control panel failed to transmit events to CS1
after 8 attempts (1
-st
CS phone number will not answer either after the 8
-th
call), then the control panel will record a “CS1 communication failed” event into the 800-event LOG and the
specific reporting code into the CS1 85-event internal buffer. In the same time, if an event of CS1 communication failed” is occurring in the system, then the specific reporting code will
be recorded into the CS2 85-event internal buffer and will be transmitted to CS2, too. Upon a new reportable event occurring, if the communication with CS1 is established, the entire list
from CS1 internal buffer, the old reporting codes, the new reporting codes and the failed communication reporting code, which is already in the list, will be reported together to the CS1.
For CS1 communication failed” event, the panel will report to CS1 the 4-digit group which is established in this section, specific to the “Communication to CS failed” event, after which
the panel will add another 2 digits of [0] and 1 digit of [1] for zone, to identify at CS1 the “CS1 communication failed” event as zone “001”.
- Any event selected in section [033] to be reported to CS2 will be sent to the 2
-nd
CS phone number, programmed in section [075]. If the control panel failed to transmit events to CS2
after 8 attempts (2
-nd
CS phone number will not answer either after the 8
-th
call), then the control panel will record a “CS2 communication failed” event into the 800-event LOG and the
specific reporting code into the CS2 85-event internal buffer. In the same time, if an event of „CS2 communication failed” is occurring in the system, then the specific reporting code will
be recorded into the CS1 85-event internal buffer and will be transmitted to CS1, too. Upon a new reportable event occurring, if the communication with CS2 is established, the entire list
from CS2 internal buffer, the old reporting codes, the new reporting codes and the failed communication reporting code, which is already in the list, will be reported together to the CS2.
For „CS2 communication failed” event, the panel will report to CS2 the 4-digit group which is established in this section, specific to the “Communication to CS failed” event, after which
the panel will add another 2 digits of [0] and 1 digit of [2] for zone, to identify at CS2 the „CS2 communication failed event as zone “002”
Section [074]: Phone Number of CS1
If the digital communicator is enabled by programming, this is the phone number that the control panel will dial first to transmit to the “central
station” the events occurred in the system.
Enter the phone number in the same way it would be dialed on a touch-tone phone. The maximum number of digits is 15.
To confirm the phone number, press [#] key after the last digit of the phone number was entered.