56
Phone CS2
Unprogrammed
After [#] key pressing, the keypad buzzer will sound 6 confirmation beeps and the panel exits the section and will wait for a new command to enter another section or [#] key to exit
the “main programming menu”.
A 2-second pause can be added by entering HEX digit D between the digits of the phone number (enter HEX digit D by pressing [*] and [3] keys).
In order to erase the phone number, press [*] key, once the panel entered this section.
Example: You may want to introduce the phone number 6802054. The following sequence will be entered: |6||8||0||2||0||5||4||#|. After [#] key pressing, the keypad buzzer will sound 6
confirmation beeps and the panel exits the section and will wait for a new command to enter another section.
Notes:
1. In case the reporting to CS is programmed in [032] section as alternate, for control panel to initiate CS reporting, at least one CS phone number must be programmed in
[074] or [75] sections. If 1
-st
CS phone number is programmed in this section, this is the phone number that the control panel will dial for first time in order to transmit to the “central
station” the events occurred in the system.
2. In case the reporting to CS is programmed in [032] section as split (or double), for control panel to initiate CS1 reporting, this phone number must be programmed in this
section. Please note that if this phone number isn’t programmed, the control panel will not initiate reporting to CS1 and will not record events into the CS1 85-event internal buffer
anymore, even there in section [033] are events selected to be reported to CS1.
3. Any time when the control panel will dial this phone number, in order to identify itself to CS, the control panel will use the first panel account which was established in section [047] and will
transmit in the 1
-st
reporting format which was established in section [049].
Section [075]: Phone Number of CS2
If the digital communicator is enabled by programming, this is the phone number that the control panel will dial first to transmit to the “central station” the events occurred in the
system.
Enter the phone number in the same way it would be dialed on a touch-tone phone. The maximum number of digits is 15.
To confirm the phone number, press [#] key after the last digit of the phone number was entered.
After [#] key pressing, the keypad buzzer will sound 6 confirmation beeps and the panel exits the section and will wait for a new command to
enter another section or [#] key to exit the “main programming menu”.
A 2 second pause can be added by entering HEX digit D between the digits of the phone number (enter HEX digit D by pressing [*] and [3] keys).
In order to erase the phone number, press [*] key, once the panel entered this section.
Notes:
1. In case the reporting to CS is programmed in [032] section as alternate, for control panel to initiate CS reporting, at least one CS phone number must be programmed in [074] or
[075] sections. If 1
-st
CS phone number doesn’t answer and if 2-nd CS phone number is programmed in this section, this is the phone number that the control panel will dial
for second time in order to transmit to the “central station” the events occurred in the system. If 1
-st
CS phone number isn’t programmed in [074] and if 2-nd CS phone number
is programmed in this section, this is the phone number that the control panel will dial in order to transmit to the “central station” the events occurred in the system. In order to identify
itself to CS the control panel will use the first panel account which was established in section [047] and will transmit in the 1
-st
reporting format which was established in section [049].
2. If the digital communicator is enabled by programming, then:
- In case the alternate reporting is selected in section [032], in order to transmit to the “central station” the events occurred in the system, this is the phone number that the control
panel will dial for second time, in case 1
-st
CS phone number doesn’t answer.
- In case the split (or double) reporting is selected in section [032], and then the panel will report to CS2 only after reporting to CS1 finished or failed. In order to identify itself to CS2 the
control panel will use the second panel account which was set in section [048] and will transmit in the 2
-nd
reporting format which was established in section [049]. Please note that if this
phone number isn’t programmed, the control panel will not initiate reporting to CS2 and will not record events into the CS2 85-event internal buffer anymore, even there in section [033]
are events selected to be reported to CS2.
3. Phones numbers in sections [074] and [075] are not programmed by default.
Section [076]: Time between Periodical Tests (in hours or minutes)
Enter 1 group of 3 digits for the time between periodical tests (001 to 255 hours or minutes).