AutoArmTime A
Unprogrammed
AutoDisarmTime A
Unprogrammed
Choose Sect:
AutoArmTime B
Unprogrammed
AutoDisarmTime B
Unprogrammed
Choose Sect:
The keypad buzzer will sound 6 confirmation beeps after the 3-digit group and the panel exits the section, waiting for a new command to enter another section.
Press [#] key instead of the 3-digit group if you want to cancel programming of this time interval.
To exit the “main programming menu”, press [#] key.
Note: For this time interval any value from 000 to 999 may be entered, but the panel will automatic adjust the introduced value by modulo 256 and will record the result in memory as
programmed value. If the result of adjustment is 0, then the periodical tests will be transmitted after every minute or hour!
Section [077]: “Guardian Round Period” / “Warning guardian round time”
Enter 2 groups of 3 digits, the first 3 digits for each „guardian round period” (001 to 255 minutes) and the second 3 digits for the warning time before each guardian round period
expires (001 to 255 minutes).
The keypad buzzer will sound 3 beeps after each 3-digit group and 6 beeps after the last one.
Note: For each these times any value from 000 to 999 may be entered, but the panel will automatic adjust the introduced value by modulo 256 and will record the result in memory as
programmed value. If any result of adjustment is 0, then the „guardian round period” and/or the „warning guardian round time” will be as they were set for 1 minute!
Section [078]: Autoarming / Autodisarming Moments for Partition A (hour: minute / hour: minute)
In order to establish the daily moments when the partition A is arming/disarming automatically, enter the hour (00 to 23) and minute (00 to 59) for arming moment and the hour (00
to 23) and minute (00 to 59) for disarming moment.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Section [079]: Autoarming / Autodisarming Moments for Partition B (hour: minute / hour: minute)
In order to establish the daily moments when the partition B is arming/disarming automatically, enter the hour (00 to 23) and minute (00 to 59) for arming moment and the hour (00
to 23) and minute (00 to 59) for disarming moment.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
RoundPeriod
060
WarningRoundT
005
, type one 3 digit number
or
[#]
Choose Sect:
, type one 3 digit number
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]