Cerber C816 - Section [081]: Activation; Deactivation Moments of PGM1 as clock timer (hour: minute; hour: minute); Section [082]: Activation; Deactivation Moments of PGM2 as clock timer (hour: minute; hour: minute); Section [083]: Activation; Deactivation Moments of PGM3 as clock timer (hour: minute; hour: minute)

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
RoundStartTime
Unprogrammed
RoundFinishTime
Unprogrammed
Choose Sect:
ActMomPGM1
Unprogrammed
DeactMomPGM1
Unprogrammed
Choose Sect:
ActMomPGM2
Unprogrammed
DeactMomPGM2
Unprogrammed
Choose Sect:
ActMomPGM3
Unprogrammed
DeactMomPGM3
Unprogrammed
Choose Sect:
To exit the “main programming menu”, press [#] key.
Section [080]: Moments for Starting / Finishing the Guardian Rounds (hour: minute / hour: minute)
In order to establish the daily moments when the guardian rounds are starting/finishing automatically, enter the hour (00 to 23) and minute (00 to 59) for starting moment and the
hour (00 to 23) and minute (00 to 59) for finishing moment.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Section [081]: Activation / Deactivation Moments of PGM1 as “clock timer” (hour: minute / hour: minute)
In order to establish the daily moments when the PGM1 defined as “clock timer” type is activating/deactivating automatically, enter the hour (00 to 23) and minute (00 to 59) for
activation moment and the hour (00 to 23) and minute (00 to 59) for deactivation moment.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Section [082]: Activation / Deactivation Moments of PGM2 as “clock timer” (hour: minute / hour: minute)
In order to establish the daily moments when the PGM2 defined as “clock timer” type is activating/deactivating automatically, enter the hour (00 to 23) and minute (00 to 59) for
activation moment and the hour (00 to 23) and minute (00 to 59) for deactivation moment.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Section [083]: Activation / Deactivation Moments of PGM3 as “clock timer” (hour: minute / hour: minute)
In order to establish the daily moments when the PGM3 defined as “clock timer” type is activating/deactivating automatically, enter the hour (00 to 23) and minute (00 to 59) for
activation moment and the hour (00 to 23) and minute (00 to 59) for deactivation moment.
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits
or
[#]
, type 2 groups of 2 digits