61
Switch to
Low zones
UnderTestVerify
Z01-Not k1
Choose Sect:
Switch to
High zones
UnderTestVerify
Z07-Not k1
DDMMYYhhmmss
010105120034
A 2-second pause can be added by entering HEX digit D between the digits of the phone number (enter HEX digit D by pressing [*] and [3] keys).
In order to erase the phone number, press [*] key, once the panel entered this section.
To exit the “main programming menu”, press [#] key.
Example: You may want to introduce the phone number 6802054. The following sequence will be entered: |6||8||0||2||0||5||4||#|. After [#] key pressing, the keypad buzzer will sound 6
confirmation beeps and the panel exits the section and will wait for a new command to enter another section.
Section [094]: Verifying of the Special Alarm Memory, produced by the “under test” sensors
In order to verify the especially alarm memory, produced by the “under test” sensors, you should just enter section [094]. For a short time you will see on the display the following
message:
Followed by:
Using the “left arrow - right arrow” key you can see if since the last resetting of the special alarm memory, performed by installer, there were in the system violations of the zones
programmed as “under test”. To reset the alarm memory of one of these zones, press the numeric key indicated on the display. In order to see the same information but for the zones
from 7/9 to 12/16, press the [*] key to switch on the “High Zones”. On display you will see for a short time the following message:
Followed by:
Finally, after verification and resetting the special alarm memory, the installer must press the [#] key.
If you press a numeric key corresponding for a under test zone that wasn’t violated since the last reset,
The keypad will reject and on the display you will see the message: “LockAttr-0”
Section [095]: Programming session of the system time and date (performed by installer)
While the system is being within “main programming menu”, in order to program/modify the system time and date,
Select section [095].
1. Programming of the system time and date can be canceled by [#] key pressing.
2. In order to enter programming session of the system time and date the installer should introduce the format below: [D/D][Mo/Mo][Y/Y][H/H][Mi/Mi][S/S].
Each 2-digit group represents the day [D/D], month [Mo/Mo], year [Y/Y], hour [H/H], minutes [Mi/Mi] and seconds [S/S].
2.1 Once the first 2-digit group corresponding the day [D/D] was entered, the keypad buzzer will sound 3 beeps and the zone 2 LED is blinking (only on KP-126Pz / KP-
164Pz). That means the control panel is waiting for second 2-digit group corresponding the month [Mo/Mo].
2.1 Once second 2-digit group corresponding the month [Mo/Mo] was entered, the keypad buzzer will sound 3 beeps and the zone 3 LED is blinking (only on KP-126Pz / KP-
164Pz). That means the control panel is waiting for third 2-digit group corresponding the year [Y/Y].
2.1 Once the third 2-digit group corresponding the year [Y/Y] was entered, the keypad buzzer will sound 3 beeps and the zone 4 LED is blinking (only on KP-126Pz / KP-
164Pz). That means the control panel is waiting for fourth 2-digit group corresponding the hour [H/H].
2.1 Once the fourth 2-digit group corresponding the hour [H/H] was entered, the keypad buzzer will sound 3 beeps and the zone 5 LED is blinking (only on KP-126Pz / KP-
164Pz). That means the control panel is waiting for fifth 2-digit group corresponding the minutes [Mi/Mi].
2.1 Once the fifth 2-digit group corresponding the minutes [Mi/Mi] was entered, the keypad buzzer will sound 3 beeps and the zone 6 LED is blinking (only on KP-126Pz /
KP-164Pz). That means the control panel is waiting for sixth 2-digit group corresponding seconds [S/S].
2.1 Once the sixth (the last) 2-digit group corresponding seconds [S/S] was entered, the keypad buzzer will sound 6 confirmation beeps and the control panel will go
back within “main programming menu”.