3-28
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
19 - THROTTLE X
20 - THROTTLE Y
21 - DHU CBK SPEED
22 - TORQUE PROFILE
DESCRIPTION MIN. MAX STEP UNIT
Determines an X value zone in the acceleration curve 10 100 10 %
Image reference 2
DESCRIPTION MIN. MAX STEP UNIT
Determines an Y value zone in the acceleration curve 10 100 10 %
Image reference 2
DESCRIPTION MIN. MAX STEP UNIT
Determines the speed reduction of the DHU 0 100 10 %
Minimum setting = maximum reduction
Maximum setting = no reduction
DESCRIPTION MIN. MAX STEP UNIT
Determines the traction motor torque 0 4 1
Minimum setting = minimum torque
Maximum value = maximum torque
VPOT MIN.
THROTTLE Y
MAX SPEED
FREQ CREEP
THROTTLE X
VPOT MAX.
THROTTLE 0
V
T
A
C
C
D
E
L
A
Y
IMAGE 2
TRACTION POTENTIOMETER CURVE
https://www.forkliftpdfmanuals.com/