4-38
47 WAITING FOR NODE
Condition for error detection
Failure of the can bus comunication. The alarm appears if the lifting logic unit receives the information of
I/O card ether traction logic unit or armrest board with a delay.
Check if the alarm appears in combination with other alarms. In this case, this alarm is consequent.
Check the dashboard’s alarms, before replacing any cards
If the alarm appears alone:
Check the can bus connector: all wires must be well connected in both the side of the wiring harness.
The alarm can be generated by a false contact
if the above tests are negative replace the lifting logic unit
48 AUX OUTPUT KO - UNUSED