4-63
0
1
2
3
4
3
6
7
8
9
10
11
12
13
14
15
16
17
18
EE PUMP STUFFING ERROR
Condition for error detection
The I/O Board receives the information from the lifting logic unit in delay
Check:
- Check the power supply to the cards
- Enter the SOFT VERS menu to see which card is not present on the can-bus line
- Can-bus pull-up resistance presence
Instrument panel 180 Ohm
MCB 180 Ohm
Arm rest 180 Ohm
- Check the connections, pins and wiring harness on the can-bus
See paragraph SYSTEM CONFIGURATION WITH MECHANICAL/ELECTRIC DISTRIBUTOR
81 INCORRECT START
Condition for error detection
Incorrect starting sequence.
The pedal or the hand direction lever has been activated before switching the truck on.
Check:
- forward, backward micros and relevant cables
See chapter 2 “ADJUSTING THE ACCELERATOR POTENTIOMETERS”
82 UNUSED
83 PEDAL WIRE KO
Condition for error detection
Failure in the signal of the accelerator potentiometer at rest. Check:
traction potentiometer (could be damaged or not correctly calibrated)
traction potentiometer wiring
See chapter 2 “ADJUSTING THE ACCELERATOR POTENTIOMETERS”
84 BAD MICRO SWITCH
Condition for error detection
Microswitch of the pedal or of the hand direction lever damaged.
See chapter 2 “ADJUSTING THE ACCELERATOR POTENTIOMETERS”
85 UNUSED