4-67
0
1
2
3
4
3
6
7
8
9
10
11
12
13
14
15
16
17
18
C3 UNUSED
C4 RETRO OPEN
Condition for error detection
Failure on the reverse lights.
Check the reverse light bulbs and the relative cables
C5 TILT_LOCK _FAULT
Condition for error detection
The alarm signals a failure in the forward/backward tilting solenoid valve EV13 coil.
The coil could be opened or disconnected.
Check:
- Value in Ohm of the coils and the relevant wiring harness.
If the problem persists replace the I/O board.
C6 LOWERING_LOCK_FAULT
Condition for error detection
The alarm signals a failure in the lifting/lowering solenoid valve EV12 coil.
The coil could be opened or disconnected.
Check:
- Value in Ohm of the coils and the relevant wiring harness.
If the problem persists replace the I/O board.
C7 STATIONARY_BRAKING_BUZZER_FAULT
Condition for error detection
The alarm signals an alarms buzzer failure.
The buzzer could be open or disconnected.
Check:
- Value in Ohm of the buzzer and respective wiring harness
If the problem persists replace the I/O board.
https://www.forkliftpdfmanuals.com/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CESAB B 215 and is the answer not in the manual?

CESAB B 215 Specifications

General IconGeneral
BrandCESAB
ModelB 215
CategoryForklifts
LanguageEnglish

Related product manuals