Troubleshooting Chart (cont’d)
Symptom Possible Cause(s) Corrective Action
Low or loss of oil pressure 1. Low crancase level.
2. Oil pickup screen clogged.
3. Faulty oil pump..
1. Check oil level. Add oil if required.
2. Drain oil from crankcase.
Remove oil pickup screen and clean.
Reinstall screen and all clean oil to
crankcase.
3. Replace oil pump.
System does not alternate
(Duplex units only)
1. Starter tripped.
2. Loose wiring in alternator.
3. Defective alternator.
4. Defective motor.
1. Reset starter. If starter trips
repeatedly, have electrical system
inspected by an electrician.
2. Check and tighten all wiring
connections.
3. Replace alternator.
4. Replace motor.