R410A50Hz Universal Outdoor Series Technical ManualFloor ceiling
104
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6.Capacity Table
Cooling
6.1 CUA-18HR1,CUA-18CR1
MODEL
CUA-18HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D 15ºC W
Total capacity kW
4.98
4.93
4.88
4.81
4.32
3.67
Input kW.
1.76
1.79
1.83
1.89
2.00
2.08
24ºC D 17ºC W
Total capacity kW
5.23
5.18
5.12
5.05
4.53
3.85
Input kW.
1.79
1.83
1.87
1.92
2.04
3.79
27ºC D 19ºC W
Total capacity kW
5.49
5.43
5.38
5.30
4.76
4.04
Input kW.
1.83
1.86
1.90
1.96
2.08
2.16
29ºC D 19ºC W
Total capacity kW
5.71
5.65
5.60
5.51
4.95
4.21
Input kW.
1.86
1.90
1.94
2.00
2.12
2.21
32ºC D 23ºC W
Total capacity kW
5.94
5.88
5.82
5.73
5.14
4.37
Input kW.
1.90
1.94
1.98
2.04
2.16
2.25
6.2 CUA-24HR1,CUA-24CR1
MODEL
CUA-24HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D 15ºC W
Total capacity kW
6.67
6.60
6.54
6.44
5.78
4.91
Input kW.
2.29
2.33
2.38
2.45
2.60
2.71
24ºC D 17ºC W
Total capacity kW
7.00
6.93
6.86
6.76
6.07
5.16
Input kW.
2.33
2.38
2.43
2.50
2.65
4.93
27ºC D 19ºC W
Total capacity kW
7.35
7.28
7.21
7.10
6.37
5.42
Input kW.
2.38
2.42
2.48
2.55
2.71
2.82
29ºC D 19ºC W
Total capacity kW
7.65
7.57
7.50
7.38
6.63
5.63
Input kW.
2.42
2.47
2.53
2.60
2.76
2.87
32ºC D 23ºC W
Total capacity kW
7.95
7.87
7.79
7.68
6.89
5.86
Input kW.
2.47
2.53
2.57
2.65
2.82
2.93
6.3 CUA-36HR1,CUA-36CR1
MODEL
CUA-36HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
43ºC
21ºC D 15ºC W
Total capacity kW
9.86
9.77
9.67
9.53
8.55
7.27
Input kW.
3.68
3.75
3.83
3.94
4.19
4.35
24ºC D 17ºC W
Total capacity kW
10.36
10.25
10.15
10.00
8.98
7.63
Input kW.
3.75
3.83
3.91
4.02
4.26
7.93
27ºC D 19ºC W
Total capacity kW
10.88
10.76
10.66
10.50
9.43
8.01
Input kW.
3.83
3.90
3.98
4.10
4.35
4.53
29ºC D 19ºC W
Total capacity kW
11.31
11.20
11.09
10.92
9.80
8.33
Input kW.
3.90
3.98
4.06
4.19
4.44
4.61
32ºC D 23ºC W
Total capacity kW
11.76
11.64
11.53
11.36
10.19
8.66
Input kW.
3.98
4.06
4.14
4.26
4.53
4.71

Related product manuals