Remote Operation
7-9
MEASure : FREQuency?
Return Parameters : <NR2>
FETCh [ : SCALar] : POWer : AC [ : REAL] ?
MEASure [ : SCALar] : POWer : AC [ : REAL] ?
Description : These queries return the true power which is being output at
output terminals in watts.
Query Syntax : FETCh : POWer : AC?
MEASure : POWer : AC?
Return Parameters : <NR2>
FETCh [ : SCALar] : POWer : AC : APParent?
MEASure [ : SCALar] : POWer : AC : APParent?
Description : These queries return the apparent power which is being output
at output terminals in volt-amperes.
Query Syntax : FETCh : POWer : AC : APParent?
MEASure : POWer : AC : APParent?
Return Parameters : <NR2>
FETCh [ : SCALar] : POWer : AC : REACtive?
MEASure [ : SCALar] : POWer : AC : REACtive?
Descrition : These queries return the reactive power which is being output at
output terminals in volt-amperes. Reactive power is computed
as: VAR =
APPARENTPO
WER REALPOWER
2 2
Query Syntax : FETCh : POWer : AC : REACtive?
MEASure : POWer : AC : REACtive?
Return Parameters : <NR2>
FETCh [ : SCALar] : POWer : AC : PFACtor?
MEASure [ : SCALar] : POWer : AC : PFACtor?
Descrition : These queries return the power factor which is being output at
output terminals. Power factor is computed as:
PF = TRUE POWER / APPARENT POWER
Query Syntax : FETCh : POWer : AC : PFACtor?
MEASure : POWer : AC : PFACtor?
Return Parameters : <NR2>
FETCh [ : SCALar] : VOLTage : ACDC?
MEASure [ : SCALar] : VOLTage : ACDC?
Description : These queries return the rms voltage which is being output at
the output terminals.
Query Syntax : FETCh [ : SCALar] : VOLTage : ACDC?
MEASure [ : SCALar] : VOLTage : ACDC?
Return Parameters : <NR2>
FETCh [ : SCALar] : VOLTage : DC?
MEASure [ : SCALar] : VOLTage : DC?
Description : These queries return the DC composition of output voltage
which is being output at the output terminals.
Query Syntax : FETCh [ : SCALar] : VOLTage : ACDC?
MEASure [ : SCALar] : VOLTage : ACDC?
Return Parameters : <NR2>