High Power DC Electronic Load 63200 Series Operation & Programming Manual
7.2.3 CURRENT Sub-system
CURRent
:STATic
:L1
:L2
:RISE
:FALL
:DYNamic
:L1
:L2
:RISE
:FALL
:T1
:T2
CURRent:STATic:L1/L2
Description Set Static Load Current to constant current mode.
Syntax CURRent:STATic:L1 <NRf+>[suffix]
CURRent:STATic:L2 <NRf+>[suffix]
Parameters For valid value range refer to respective specification.
Example CURR:STAT:L1 20 Set Constant Current = 20A for Static
Load L1.
CURR:STAT:L2 10 Set Constant Current = 10A for Static
Load L2.
CURR:STAT:L1 MAX Set Constant Current = maximum
value for Static Load L1.
CURR:STAT:L2 MIN Set Constant Current = minimum value
for Static Load L2.
Query Syntax CURRent:STATic:L1?
CURRent:STATic:L2?
CURRent:STATic:L1? MAX
CURRent:STATic:L2? MIN
Return Parameters <NR2> [Unit=Ampere]
Query Example CURR:STAT:L1? Return the set current value of Static
Load L1.
Return Example 3.12
CURRent:STATic:RISE/FALL
Description Set the current slew rate for constant current static mode.
Syntax CURRent:STATic:RISE <NRf+>[suffix]
CURRent:STATic:FALL <NRf+> [suffix]
Parameters For valid value range refer to respective specification.
Example CURR:STAT:RISE 2.5 Set rise slew rate to 2.5A/µS for
static load.
7-10