Page #46 background imageLoading...
Page #46 background image
User Instructions
TM
Appendix A
microTHERM™: CMX-180 Open and Closed-loop Electrical Schematic
42
Heater
9 KW
10.8 AMP
Pump
Motor
80 VA
480 : 120 VAC
(See Transformer Wire Diagram)
OL
1M-1
2L1
2T1
2L2
2L3
2T2
2T3
1C
1T11L1
1L2 1T2
1L3 1T3
3T3
3T1
L1
L2
L3
GND
1
1F
Pump
Overload
Heater
Overtemp
Cooling Solenoid
(See Note 1)
Heater
Control
6, 14 Motor Control
8, 9
Pump
2
1PB-2
Start
1M-1
14
13
14
13
12
5
6
W
R
R
X2
X1
1M
A1
A2
95
96
7
1C
9
54
53
8
10
Output #3
11
OL-1
98
97
12
1M-2-2
62
61
13
Type J
T/C
1 TE
See Note #2
1ITC
1
2
3
4
5
6
7
8
9
19
20
21
22
23
24
25
26
27
10
11
12
13
14
15
16
17
18
Output #4
+
-
1M-2-1
OL
Customer
Supplied
480 VAC
3/4 H.P.
1.7 FLA
GND
2F
3F
4F
Snubber
Snubber
12
2104-TT1
10
6
7
Customer
Connection
Remote Start
6
7
6
5
Customer
Connection
Remote Stop
11
1PB–1
Stop
4
10TC–1
Thermal
Switch
3
1
2
3
4
5
6
7
8
9
10
11
12

Other manuals for Chromalox MicroTherm CMX Series