2. INSTALLATION
2.1 Location of the control terminal and the heat pump
2.1.1 Control terminal
At delivery, the HomeConnect control terminal is located behind the GeoCIAT
TM
Modular unit.
Location
Before fixing the control terminal in place, check the range of the radio signal. This should be at the maximum level.
If this is not the case, you can also move the heat pump a few centimetres to ensure optimal transmission of its radio signal.
Selecting a location
The terminal operates permanently as a room thermostat. It is therefore essential to place the control terminal inside the home,
within the environment to be monitored and away from heat sources (chimney, radiator, sunlight), draughts (windows, doors) and
areas of activity.
Mounting
The terminal is supplied with a wall mounting plate (base) and a base.
The wall mounting plate should be affixed using screws and wall plugs (FS Ø4 mm flat head slotted screws, Ø5 mm wall plugs),
which are not supplied, using the holes marked on the mounting plate.
The battery compartment has ribs on either side to hold the terminal on its mounting plate.
Once the mounting plate is affixed to the wall, slide the terminal into place.
The terminal is positioned in the same way on the base.
Outdoor sensor
Control terminal