3-2 Turning Up the System
3930 Service Delivery Switch Hardware Installation and Start-up Manual
009-3223-001 Standard Revision E
Copyright
©
2012-2014 Ciena
®
Corporation January 2014
Logging in through the Serial Console Port
On 3902, 3916, 3930, 3931, and 5150 switches, the serial console port
requires a null modem cable connected to a male DB-9 to male RJ-45 cable
to connect to the RJ-45 connector.
Other switches in the product family, such as the 3911, 3920, 3940, 3960, and
5140, support an EIA-232 connector requiring a DB-9 cable.
Before you begin, ensure the 3930 is powered on.
For information on provisioning commands for the serial-console interface,
see 39XX/51XX Command Reference.
For a procedure see “Logging in through the Serial Console Port” on page 3-8.
Creating a New User Account
The 3930 is preconfigured with default user accounts. The default user
accounts are common to all Ciena Carrier Ethernet products and are not
confidential. When you turn-up the system you need to configure new user
accounts and delete the default accounts in order to protect the system.
The default user accounts and passwords are summarized in Table 3-1.
Table 3-1
Default User Accounts and Passwords
User Name Password Access Rights Access Level
user < empty > Read-only Limited User — able to execute commands that do not
change the state of the system in a significant way or
change the configuration of the device. For example,
“show” commands.
admin www Read/write Admin User — includes all the privileges of the Limited
User and can make significant system state changes,
modify the configuration, and perform execute
commands.
su wwp Read/write/
create
Super User — includes all the privileges of the Limited
User and can make significant state changes, modify
the device configuration, and perform execute
commands.
gss pureethernet Diagnostic Diag User — includes all the privileges of the Super
User and can center special hardware diagnostic
commands as instructed by the Ciena Customer
Support Department during advanced troubleshooting.
Note: User names and passwords are limited to 16 characters each.