If additional chlorine is required (due to heavy bather loads, for
example), use Sodium Hypochlorite to maintain an appropriate
chlorine residual in the water.
DO NOT add acid or other concentrated chemicals directly to the
skimmer. This may damage the cell.
Check the expiration date of any test kits as test results may be
inaccurate if used after that date.
When replacing the cell, only use replacement cells having a label
that clearly states that it is the replacement for this Universal Series
/ Si Series model.
Proper pool chemistry must be maintained at all times. For outdoor
pools, chlorine residuals can be protected from destruction by
sunlight by addition of stabilizer (cyanuric acid).
The use of dry acid may damage the salt cell and is not
recommended. When using liquid acid, always add acid to water,
never water to acid.
For proper sanitation, spas must be completely drained periodically.
The number of days between COMPLETE SPA DRAINAGE is equal to
the volume of the spa water in gallons, divided by 10 times the
maximum number of daily spa users. Refill spa with water and
repeat initial startup instructions on page 3 of this manual.
Ensure that the Universal Series installation does not constitute a
cross connection with the local potable water supply. Consult local
plumbing codes.
Note: Some local codes may require external grounding source.
Check your local ordinances.
To reduce the risk of electric shock, the ground wire (green wire) on
the power cord must be connected to the grounding means
provided in the electric supply service panel.
One bonding lug for US models is provided on the external surface.
To reduce the risk of electric shock, connect the local common
bonding grid in the area of the swimming pool, spa, or hot tub to
these terminals with an insulated or bare copper conductor not
smaller than 8 AWG US.