3A-14 P/N 13772-004
Section 3A Cirrus Design
Abnormal Procedures SR22
Low Alternator 2 Output
ALT 2 Caution (Failure)
1. ALT 2 Circuit Breaker ..............................................CHECK & SET
2. ALT 2 Master Switch ...........................................................CYCLE
If alternator does not reset (low A2 Current and M2 voltage less
than M1 voltage):
3. ALT 2 Master Switch ................................................................OFF
4. Continue Flight, avoiding IMC or night flight as able (reduced
power redundancy).
Amplification
Alternator 2 output is low, indicative of alternator failure; isolated Alt 2
failure will not typically be associated with any other unusual
indications, cautions or warnings (Alt 1 will pick up all loads).