Cirrus Design Section 5
SR22 Performance Data
P/N 13772-004 5-11P/N 13772-004 5-11
Outside Air Temperature for ISA Condition
Press
Alt
Feet
ISA-40°C ISA-20°C ISA ISA+10°C ISA+20°C
°C °F °C °F °C °F °C °F °C °F
SL -25 -13 -5 23 15 59 25 77 35 95
1000 -27 -18 -7 18 13 54 23 72 33 90
2000 -29 -20 -9 16 11 52 21 70 31 88
3000 -31-24-1112 9 4819662984
4000 -33-27-139 7 4517632781
5000 -35-31-155 5 4115592577
6000 -37-34-172 3 3813562374
7000 -39 -38 -19 -2 1 34 11 52 21 70
8000 -41-42-21-6 -13010482066
9000 -43 -45 -23 -9 -3 27 7 45 17 63
10000 -45 -49 -25 -13 -5 23 5 41 15 59
11000 -47 -52 -27 -16 -7 20 3 38 13 56
12000 -49 -56 -29 -20 -9 16 1 34 11 52
13000 -51 -59 -31 -23 -11 13 -1 31 9 49
14000 -53 -63 -33 -27 -13 9 -3 27 7 45
15000 -55 -67 -35 -31 -15 6 -5 23 5 41
16000 -57 -71 -37 -34 -17 2 -7 20 3 38
17000 -59 -75 -39 -38 -19 -2 -9 16 1 34
17500 -60 -76 -40 -40 -20 -3 -10 14 0 32