Cirrus Design Section 4
SR22 Normal Procedures
P/N 13772-004 4-15P/N 13772-004 4-15
Maximum Power Fuel Flow
Target fuel flow is indicated by the top of a dynamically calculated
green arc displayed on the fuel gage. Target fuel flow should be
maintained at the top of this arc by use of the mixture lever.
The fuel flow values in the table below were demonstrated to obtain
the takeoff and climb performance presented in Section 5.
• Note •
Excessively rich mixture will occur if the Mixture control is set to FULL
RICH above 7500 feet pressure altitude.
Pressure
Altitude
Target
Fuel Flow
Pressure
Altitude
Target
Fuel Flow
Pressure
Altitude
Target Fuel
Flow
0 27.1 7000 21.4 14,000 17.5
1000 26.2 8000 20.5 15,000 16.9
2000 25.1 9000 19.9 16,000 16.7
3000 24.3 10,000 19.5 17,000 16.2
4000 23.6 11,000 18.8 17,500 16.1
5000 22.8 12,000 18.4
6000 22.1 13,000 17.9