13 Miscellaneous Usage and Configuration Guidelines
Using the Mode Button
Using the Mode button (see Figure 6) you can:
Reset the AP to the default factory-shipped configuration.
Clear the AP internal storage, including all configuration files and the regulatory domain
configuration.
Boot loader warnings Blinking Amber Configuration recovery in progress (Mode button
pushed for 2 to 3 seconds)
Red Ethernet failure or image recovery (Mode button
pushed for 20 to 30 seconds)
Blinking Green Image recovery in progress (Mode button
released)
Boot loader errors Red DRAM memory test failure
Blinking Red and
Amber
FLASH file system failure
Blinking Red and off One of the following:
Environment variable failure
Bad MAC address
Ethernet failure during image recovery
Boot environment failure
No Cisco image file
Boot failure
Cisco Access Point
Operating System
(AP-OS) errors
Red Software failure; try disconnecting and
reconnecting unit power
Cycling through Red,
Green, Amber and off.
General warning; insufficient inline power
Table 2 LED Status Indications (continued)
Message
Type
LED State Message
Meaning