Internal and External Flash Storage
The ASA contains one internal USB flash drive, and a standard USB Type A port that you can use to attach
an external device. The USB port can provide output power of 5 volts, up to a maximum of 500 mA (5 USB
power units).
Internal USB Device
An embedded eUSB device is used as the internal flash; it is identified as disk0.
External USB Drive (Optional)
You can use the external Type A USB port to attach a data-storage device. The external USB drive
identifier is disk1. When the ASA is powered on, a connected USB drive is mounted as disk1 and is
available for you to use. Additionally, the file-system commands that are available to disk0 are also
available to disk1, including copy, format, delete, mkdir, pwd, cd, and so on.
If you insert a USB drive with more than one partition, only the first partition is mounted.
FAT-32 File System
The ASA only supports FAT-32-formatted file systems for the internal eUSB and external USB drives.
If you insert an external USB drive that is not in FAT-32 format, the system mounting process fails, and
you receive an error message. You can enter the command format disk1: to format the partition to
FAT-32 and mount the partition to disk1 again; however, data might be lost.
Solid State Drive
The ASA 5506-X and ASA 5506W-X ship with an SSD installed that provides storage support. The SSD has
50 GB of useable space and is not field-replaceable. You must return the entire ASA to Cisco for drive
replacement. The SSD is used by the software; there is no user access to the SSD.
The ASA 5506H-X ships with a ruggedized SSD installed that provides storage support. The SSD is an
industrial-rated part so that it operates over the extended temperature range that the ASA 5506H-X supports.
The SSD has 50 GB of useable space and is not field-replaceable. You must return the entire ASA to Cisco
for drive replacement. The SSD is used by the software; there is no user access to the SSD.
Power Supply Modules
The ASA 5506-X and ASA 5506W-X ship with a 12V brick power supply that provides 60 W.
The ASA 5506H-X ships with a ruggedized 5V-5.3V barrel power supply that provides 22 W. The power
supply supports an extended temperature range of -25°C to 60°C. Or you can order an optional DC power
supply that supplies 24V DC (part number PWR2-20W-24VDC) or 20W 20-60V DC (part number
PWR2-22W-20-60VDC).
Hardware Specifications
The following table contains hardware specifications for the ASA.
Cisco ASA 5506-X, ASA 5506W-X, and ASA 5506H-X Hardware Installation Guide
11Online Only
Overview
Internal and External Flash Storage

Other manuals for Cisco ASA 5506-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASA 5506-X and is the answer not in the manual?

Cisco ASA 5506-X Specifications

General IconGeneral
ModelASA 5506-X
Firewall Throughput750 Mbps
Maximum Firewall Connections50, 000
Maximum VPN Peers50
Integrated Ports8 x 1 GE
Stateful Inspection Throughput750 Mbps
Weight4.4 lb (2 kg)
Firewall Throughput (Multiprotocol)750 Mbps
Firewall Throughput (Application Visibility and Control AVC)250 Mbps
Concurrent Sessions50, 000
New Connections per Second10, 000
IPsec VPN Throughput100 Mbps
Interfaces8 x 1 GE
Memory4 GB
Flash Memory8 GB
Form FactorDesktop
VPN Throughput100 Mbps
Maximum Concurrent Sessions50, 000
New Sessions per Second10, 000
Operating Temperature32 to 104°F (0 to 40°C)
Storage Temperature-13 to 158°F (-25 to 70°C)
Power SupplyExternal
Humidity10% to 90% non-condensing

Related product manuals