The Firepower 2130 and 2140 have a removable fan tray with 3 + 1 redundant fans that are hot-swappable.
The fan tray is installed in the rear of the chassis. Any one fan can fail indefinitely and the system continues
to function. When a fan fails, the remaining fans automatically spin up to full speed.
The fan LED is located on the front of the chassis. See Product ID Numbers, on page 30 for a list of the PIDs
associated with the 2100 series fans.
For More Information
• See Front Panel LEDs, on page 10 for the location and description of the fan LED.
• See Remove and Replace the Fan Tray, on page 78 for the procedure for removing and replacing the
fan tray.
SSDs
The Firepower 2110 and 2120 have two SSD slots. These models ship with one 100-GB SSD installed in slot
1. The Firepower 2130 and 2140 have two SSD slots. These models ship with one 200-GB SSD installed in
slot 1. See Product ID Numbers, on page 30 for a list of the PIDs associated with the 2100 series SSDs.
You can use the second SSD slot to upgrade to the MSP. The MSP must be installed in the second slot. The
second SSD slot remains empty unless you install the MSP in the second slot. The MSP stores threat detection
results for use in future analysis. It supports the Advanced Malware Protection (AMP) software feature. It is
used as both storage and as the Malware application repository. RAID is not supported.
You cannot swap SSDs between different Firepower platforms. For example, you cannot use a 4100 series
SSD in a 2100 series security appliance.
Caution
The 100-GB SSD is restricted to the 2110 and 2120 models. The 200-GB SSD is restricted to the 2130 and
2140 models. Do not mix them.
Note
Although the hardware supports hot swapping for the SSDs, the software does not, so you must power down
the chassis before removing and replacing them.
For More Information
• See Front Panel LEDs, on page 10 for the location and description of the SSD LEDs on the front panel.
• See Remove and Replace the SSD, on page 68 for the procedure for removing and replacing the SSD.