Cisco Preparative Procedures & Operational User Guide
© 2016 Cisco Systems, Inc. All rights reserved.
NOTE! After changing the management IP address, you will need to reestablish any
connections to Firepower Chassis Manager or the FXOS CLI using the new address.
Changing the Application Management IP
You can change the management IP address on the application(s) attached to your FXOS chassis from the
FXOS CLI. To do so, you must first change the IP information at the FXOS platform level, then manually
propagate the changes to the application level.
1) Connect to the FXOS CLI.
2) Scope the security module:
scope slot slot_number
3) Configure the new management bootstrap parameters.
set virtual ip ip_address mask network_mask gateway gateway_ip_address
For clustered configuration:
set virtual ip ip_address pool start_ip end_ip mask network_mask gateway
gateway_ip_address
4) Scope the application.
scope app-instance asa_or_ftd
5) Clear the management bootstrap information.
clear mgmt-bootstrap
6) Exit management bootstrap configuration scope.
Exit
7) Commit the configuration:
commit-buffer
8) Connect to the console of the security module.
9) Change the virtual IP, mask, and gateway values to the exact values used in step 3.
set virtual ip ip_address netmask network_mask gw gateway_ip_address
For clustered configuration:
set virtual ipv ip_address pool start_ip end_ip mask network_mask gateway
gateway_ip_address
10) Commit the configuration:
commit-buffer

Table of Contents

Other manuals for Cisco Firepower 4110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 4110 and is the answer not in the manual?

Cisco Firepower 4110 Specifications

General IconGeneral
Power SupplyDual, hot-swappable
Form Factor1RU
Firewall Throughput (Multiprotocol)10 Gbps
Number of 10GE (SFP+) Interfaces8
Number of 40GE (QSFP+) Interfaces2
Redundant Power SupplyYes
Memory32 GB
Ports8 x 10GE, 2 x 40GE
Concurrent Sessions8 Million
Number of 10/100/1000 Interfaces8
Maximum Connections8 Million
Management Ports1 x RJ45
Data Ports8 x 10GE, 2 x 40GE
ProcessorIntel Xeon E5-2600

Related product manuals