Ground connection1
Step 4
If necessary, strip the other end of the ground wire and connect it to a reliable earth ground such as a grounding rod or
appropriate ground point on a grounded pole. Length of the ground cable should not exceed 1 meter, and 0.5 meter is
preferred. Use supplied oxide inhibitor on the grounded interface.
Wiring the Access Point DC Power
To wire the access point to a DC power source:
Procedure
Step 1
Verify that the access point is grounded (see Grounding the Access Point, on page 19).
Step 2
Connect the power lead to the PWR connector by turning the cable clockwise, as shown in the following figure.
21