Configuring VCoP Smart SFP
Before You Begin
Ensure MPLS and IGP are active between the PE nodes.
VCoP smart SFP supports the following valid CEP Pseudo Wire (PW) configurations:
CEP PWsMode
Note
3* STS-1 or 1* STS-3cOC-3
Valid mix of STS-1, STS-3c or STS-12cOC-12
1*STS-1T3
You can configure VCoP smart SFP on OC-3 or OC-12 mode.
1
Enable VCoP smart SFP using the platform command.
2
Configure controller for CEM circuits.
3
Configure xConnect for CEM circuit.
You can configure VCoP smart SFP on T3 mode.
1
Enable VCoP smart SFP using the platform command.
2
Configure controller for CEM circuits.
3
Configure cablelength.
4
Configure xConnect for CEM circuit.
Configuring VCoP Smart SFP on OC-3
Enabling VCoP Smart SFP on OC-3
You can enable VCoP smart SFP for STS1 and STS-3c channels on OC-3.
enable
configure terminal
platform smart-sfp interface GigabitEthernet 0/0/8 type OC-3
exit
Configuring Framing for CEM Circuits for STS-1 on OC-3
enable
configure terminal
controller SONET 0/0/8
framing sonet
sts-1 1
5