FEC mode : O-FEC
AINS Soak : None
AINS Timer : 0h, 0m
AINS remaining time : 0 seconds
Laser Squelching
You can enable laser squelching on ethernet controllers. When laser squelching is enabled, the laser is shut
down in the event of trunk faults (LOS, LOF) and a SQUELCHED alarm is raised.
To configure laser squelching on the ethernet controllers, use the following commands:
configure
controller HundredGigECtrlr Rack/Slot/Instance/Port
laser-squelch
commit
The following is a sample where laser squelching is enabled on the ethernet controller.
RP/0/RP0/CPU0:ios#configure
RP/0/RP0/CPU0:ios(config)#controller HundredGigECtrlr 0/1/0/10
RP/0/RP0/CPU0:ios(config-eth-ctrlr)#laser-squelch
RP/0/RP0/CPU0:ios(config-eth-ctrlr)#commit
The following is a sample to view the laser squelch status on the controller.
RP/0/RP0/CPU0:ios#show controller HundredGigECtrlr 0/1/0/10
Fri Feb 22 15:18:47.011 UTC
Operational data for interface HundredGigECtrlr0/1/0/10:
State:
Administrative state: enabled
Operational state: Up
LED state: Green On
Maintenance: Disabled
AINS Soak: None
Total Duration: 0 hour(s) 0 minute(s)
Remaining Duration: 0 hour(s) 0 minute(s) 0 second(s)
Laser Squelch: Enabled
Phy:
Media type: Not known
Statistics:
FEC:
Corrected Codeword Count: 0
Uncorrected Codeword Count: 0
Autonegotiation disabled.
Operational values:
Speed: 100Gbps
Duplex: Full Duplex
Flowcontrol: None
Loopback: None (or external)
BER monitoring:
Not supported
Configuring Controllers
17
Configuring Controllers
Laser Squelching