1-48
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G9 Install the Alarm Expansion Panel (ANSI Only)
Figure 1-22 Installing Standoffs and the AEP
Step 4
Insert and tighten three screws to secure the AEP to the backplane.
Step 5 Connect the AEP cable to the backplane and AEP:
a. Connect the 10 colored wires to the wire-wrap pins on the backplane. Figure 1-23 shows where the
cable wires are connected. Table 1-2 shows AEP and AIC-I signals that each wire carries.
b. Plug the other end of the AEP cable into AEP connector port.
Figure 1-23 AEP Wire-Wrap Connections to Backplane Pins
78403
AEP cable
Connector
Wires