Chapter 1 Install the Shelf and Common Control Cards
NTP- G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections
Step 6 Continue with the “NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections”
procedure on page 1-49.
Stop. You have completed this procedure.
NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin
Connections
Caution Always use the supplied ESD wristband when working with a powered ONS 15454 ETSI. Plug the
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Table 1-2 Pin Assignments for the AEP
AEP Cable Wire Backplane Pin AIC-I Signal AEP Signal
Black A1 GND AEP_GND
White A2 AE_+5 AEP_+5
Slate A3 VBAT– VBAT–
Violet A4 VB+ VB+
Blue A5 AE_CLK_P AE_CLK_P
Green A6 AE_CLK_N AE_CLK_N
Yellow A7 AE_DIN_P AE_DOUT_P
Orange A8 AE_DIN_N AE_DOUT_N
Red A9 AE_DOUT_P AE_DIN_P
Brown A10 AE_DOUT_N AE_DIN_N
Purpose This procedure installs alarm, timing, LAN, and craft wires on the
ONS 15454 shelf. These wires are attached to the mechanical interface card
(MIC) FMECs on the ETSI shelf and are attached to the backplane on the
ANSI shelf.
Tools/Equipment Connectors according to function
Twisted #22 or #24 AWG (0.51 mm² or 0.64 mm²) shielded wires for LAN
or craft
75-ohm coaxial cable with 1.0/2.3 miniature coax connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) alarm wires
Prerequisite Procedures NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only), page
1-30
NTP-G5 Remove the Backplane Covers (ANSI Only), page 1-28
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None