NTP- G11 Install an External Wire-Wrap Panel on the AEP (ANSI Only)
Step 3 Return to your originating procedure (NTP).
NTP-G11 Install an External Wire-Wrap Panel on the AEP
(ANSI Only)
Step 1 Position the lower cover over the AEP. Make sure that the AEP AMP Champ connectors protrude
through the cutouts in the lower cover (Figure 1-26).
Table 1-8 Craft Interface Pin Assignments
Pin Field Contact Function
Craft A1 Receive
A2 Transmit
A3 Ground
A4 DTR
Purpose This procedure connects an external wire-wrap panel to the
ONS 15454 ANSI AEP to provide the physical alarm contacts for the AEP.
Tools/Equipment External wire-wrap panel
Prerequisite Procedures NTP-G9 Install the Alarm Expansion Panel (ANSI Only), page 1-46
Required/As Needed As needed
Onsite/Remote Onsite