EasyManua.ls Logo

Cisco ONS 15454 ETSI - Install an External Wire-Wrap Panel on the AEP (ANSI Only)

Cisco ONS 15454 ETSI
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-60
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G11 Install an External Wire-Wrap Panel on the AEP (ANSI Only)
Step 3 Return to your originating procedure (NTP).
NTP-G11 Install an External Wire-Wrap Panel on the AEP
(ANSI Only)
Step 1 Position the lower cover over the AEP. Make sure that the AEP AMP Champ connectors protrude
through the cutouts in the lower cover (Figure 1-26).
Table 1-8 Craft Interface Pin Assignments
Pin Field Contact Function
Craft A1 Receive
A2 Transmit
A3 Ground
A4 DTR
Purpose This procedure connects an external wire-wrap panel to the
ONS 15454 ANSI AEP to provide the physical alarm contacts for the AEP.
Tools/Equipment External wire-wrap panel
Prerequisite Procedures NTP-G9 Install the Alarm Expansion Panel (ANSI Only), page 1-46
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None

Related product manuals