Cisco UCS C210 M2 General-Purpose Rack-Mount Server
CONFIGURING the SERVER
19
Approved Configurations
(1) Integrated SATA RAID 0/1 controller
■ Choose none of the options listed in Table 6. In this case, the integrated RAID 0/1 controller
will be used.
(2) Optional RAID controller
■ Choose one of the RAID controllers options (with or without battery backup) listed in
Table 6.
(3) Optional RAID configuration
■ Choose one of the RAID configuration options listed in Table 6.
Caveats
■ The MegaRAID cards (LSI MegaRAID SAS 9280-4i4e or LSI MegaRAID SAS 9261-8i) must be
installed in PCIe slot #4. Refer to
Figure 3 on page 5 for PCIe slot numbering.
■ If you choose the mezzanine RAID controller card, you will still have all five PCIe slots
available for adding optional cards.
■ The two optional plug-in RAID controllers are each half-height PCIe cards. If you choose one
of these optional cards, you will still have four slots available for adding optional PCIe cards.
■ You can choose only one RAID controller (integrated controller, mezzanine card controller, or
one plug-in PCIe controller).
■ You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is
pre-configured at the factory. If you do not choose a RAID configuration, the disks will be
configured as a JBOD.
NOTE: If an optional RAID configuration is not chosen, the disks will be configured as
a JBOD.